Workmanship Guaranteed
Licensed & Insured
Upfront Fair Pricing
Finance Available
Emergency Heat Pump Repair Available 24/7
Carrara systems cop a mixed bag: leaf litter off Emerald Lakes, breezy afternoons over Palm Meadows, and the odd power blip around the stadium precinct. If your heat-pump unit hums all night, throws mystery codes, or plateaus at “lukewarm”, Todd’s Plumbing & Electrical will sort it — one visit, all trades.
Licences: QBCC 1126780 • Electrical Licence: 71053
Call: 0482 080 423
Tri-trade crew: plumbing + electrical + refrigeration in one appointment
Instrumented testing: airflow, coil temps, electrics, water-side flow — no guesswork
Fixed price you approve before tools come out
Keep-you-going options: element-only mode (if fitted) or a temporary hot water unit
Strata/estate friendly around Gooding Dr, Nerang–Broadbeach Rd and the Emerald Lakes terraces
1) Air side gets choked
Fine dust from construction pockets + leaf fluff mats the evaporator coil. Fans get loud, defrost drags, nights run long.
Our move: coil clean, fan amperage test, confirm defrost logic and drainage.
2) Timers drift after short outages
Event nights near the stadium? A 30–60 min clock shift can make the unit miss off-peak, leaving you lukewarm by evening.
Our move: correct the controller clock, verify element/compressor draw, re-set schedules.
3) Sensors tell half-truths
A tank or coil thermistor drifting 8–15 °C fools the controller into thinking water is “done” or the coil is “frozen”.
Our move: cross-check sensor readings against actual temps; replace out-of-spec parts.
4) Plumbing valves undo good work
Tempering/NRV valves in older townhouses off Gooding Dr can stick or scale — storage is hot but taps feel tepid.
Our move: test/replace valves, set safe outlet temperature, confirm stability at fixtures.
5) SEQ specials: ants, geckos, moisture
Control boxes near gardens or canals invite pests; you’ll see nuisance RCD trips and buzzing relays.
Our move: safe isolation, board/wiring inspection, replace compromised components.
Complaints: night drone, “ice” icon, hit-and-miss mornings.
Findings: coil matted; weak fan capacitor; tank sensor ~12 °C low; controller 50 mins slow.
Fix: deep coil clean, new cap + sensor, schedule corrected, defrost verified, tempering valve reset.
Outcome: quiet unit, steady ~55–60 °C storage, no overnight thrash.
Airflow & refrigeration — coil state, fan speed, non-invasive discharge/suction temps, start/run capacitors, vibration/noise clues
Electrical — supply quality, RCD behaviour, controller logic, element/compressor current draw
Plumbing — inlet pressure, tempering/NRV performance, leaks, anode (where applicable)
Proof — outlet/storage temps + recovery time, photos for strata/insurers
Coil clean & drain clear
Fan motors and capacitors
Tank/coil thermistors
Tempering & non-return valves
Element & thermostat (where fitted)
Controller re-programming and clock/tariff corrections
Corroded unions & seals
Repair when the tank is sound and the fault is a component (sensor, fan, capacitor, valve, element).
Replace when the cylinder is corroded, compressors keep faulting, or spares are obsolete. We’ll size a new heat pump for your household and tariff, install it, remove the old unit, and register warranties.
Stiebel Eltron (WWK) • Rheem (Ambiheat/HDc) • Rinnai • Sanden Eco • Reclaim Energy • iStore • Chromagen • Thermann • Dux Airoheat • Quantum (older)
Snap the rating/serial label on the unit
Note any fault codes or flashing icons
Active leak? Turn off the isolation valve
Tripping? Leave the HWS breaker off until we arrive
Call 0482 080 423 or text your unit-label photo with a one-liner about the fault. We’ll lock a time and outline the plan.
No. That’s usually a clogged coil or weak fan capacitor. We clean the coil, test the fan/cap and verify defrost so it runs quietly.
Often. If the controller clock drifted or sensors are off, recovery slips. We correct timers, verify draw and replace out-of-spec sensors.
Best to leave it off. Trips point to moisture, a failing element/capacitor or a control-board issue. We test safely and isolate the culprit.
Usually a tempering valve problem. We test/replace and set a safe outlet temperature.
Generally yes: element-only mode (if fitted) or a temporary unit until parts arrive.
Same day service at no extra cost
All brands, makes and models
Get hot water today
Over 20 years in business
Solar accredited plumbers & elecricians
Fully insured
We have honesty & integrity
We carry temporary hot water systems so if for any reason it cant be fixed on the day you can get hot water now!