
Workmanship Guaranteed
Licensed & Insured
Upfront Fair Pricing
Finance Available
Acreage plumbing behaves differently: long pipe runs, variable water pressure, tank/spring supply, and powered sheds where cylinders live. When the water goes cold, you need techs who can diagnose the fault, not guess. Todd’s Plumbing & Electrical brings dual-licensed trades to Tallebudgera—we fix the plumbing and the electrics in one visit and get your showers back up to temp fast.
Licences: QBCC 1126780 • Electrical Licence: 71053
Call: 0482 080 423

Is your hot water system leaving you in the cold? For fast, reliable, and affordable hot water repair in Robina, trust the local experts at Todd's Plumbing & Electrical. We're available 24/7 to restore your hot water and your comfort.
When your hot water fails, it's more than an inconvenience; it's a major disruption to your daily life. From cold showers to unwashed dishes, a faulty hot water system can bring your household to a standstill. At Todd's Plumbing & Electrical, we understand the urgency of hot water problems. That's why we offer prompt, professional, and guaranteed hot water repair services across Robina and the surrounding Gold Coast suburbs. Our licensed and experienced technicians are equipped to handle any hot water emergency, ensuring you get back to your routine as quickly as possible.
Licences: QBCC 1126780 • Electrical Licence: 71053
Call: 0482 080 423

No hot water ➜ failed element/ignition or tripped supply ➜ element/thermostat replacement (electric), pilot/burner service (gas)
Power trips when heating ➜ earth leakage from element or wet wiring in shed ➜ isolate circuit, replace element/tails, IR test & verify RCD/MCB
Water too hot/too cold ➜ drifting thermostat or tempering valve ➜ replace and commission to compliant set-point
Constant flow from relief pipe ➜ faulty TPR valve or over-temp/over-pressure ➜ replace TPR, test expansion/pressure, check stat cut-out
Hot water runs out early ➜ undersized cylinder or off-peak not charging ➜ element capacity check, Tariff 31/33 testing, upgrade advice
Heat pump noisy/ineffective ➜ low ambient, fan/compressor fault, sensor error ➜ test sensors, fan/compressor, recharge/replace as needed
Solar hot water lukewarm ➜ failed pump/controller or air lock ➜ replace pump, bleed loop, test controllers & valves
We stock elements, thermostats, TPR & tempering valves, anodes, pumps/controllers (solar), sensors (heat pump) and common fittings—so most Tallebudgera jobs are first-visit completions.
Electric (single/dual element, off-peak controlled load)
Gas storage & instantaneous (pilot, burner, regulators)
Solar hot water (circulation pumps, controllers, panels, valves)
Heat pumps (compressors, fans, thermistors, control boards)
Rheem • Rinnai • Dux • Aquamax • Vulcan • Thermann • Bosch • Envirosun • Everhot
Dual-trade techs: one team handles water & electrics
Acreage-aware: long runs, tank water, shed installs, pressure issues
Upfront pricing after diagnosis—no trial-and-error bills
Genuine parts and tidy reinstatement of pipework/insulation
Advice on capacity upgrades, off-peak charging and efficiency (solar/heat pump)

Water hotter/colder than usual or runs lukewarm at night (off-peak/thermostat issue)
Clicking at the board when the cylinder should be heating (contactor/timer)
White crust at fittings, or TPR pipe running constantly
Rust streaks on the casing; tank age 10+ years
Power bills creeping up after longer heat-up cycles

Surfers Paradise 4217 plus Main Beach, Chevron Island, Isle of Capri, Budds Beach, Paradise Waters, Bundall, Broadbeach (north), Southport (south).

If the RCD trips, the TPR won’t stop, the heat pump is howling, or solar won’t reheat—book a same-day hot water repair in Tallebudgera.
Phone: 0482 080 423

Aquamax
Beasely
Bosch
Dux
Edwards
Everhot
Leda
Quantum
Reece
Rheem
Rinnia
Sandal
Saxon
Stiebel
Vulcan
Yes. We check strainers, pressure/flow and valve selection so the cylinder heats safely and mixers temper correctly.
My off-peak hot water isn’t reheating overnight.
We test Tariff 31/33 feeds, time switches/contactors and elements. If needed, we can reconfigure to boost/peak temporarily.
No. Brief dripping during heating is fine; constant flow signals a faulty TPR or over-pressure. We test/replace and verify temperatures.
Yes—fan/compressor checks, defrost cycles, sensor testing and siting advice to improve performance.
Cloud cover reduces gain, but if it never recovers we test pump, controller, non-return valves, bleed air and check booster wiring.
If the tank leaks or the unit is 10+ years old with recurring faults, replacement is usually cheaper long-term. Otherwise targeted repairs (element/thermostat/valves/pumps) are cost-effective.
Absolutely. We size for household demand, run lengths and off-peak availability, then commission the tempering valve to code.






