On the ridgelines above Nerang, heat-pump hot water units cop gusty afternoons, leaf litter and the odd summer brownout. If yours rumbles through the night, flashes a snowflake symbol, or never climbs past lukewarm, Todd’s Plumbing & Electrical will get it back to proper hot water — plumbing, electrical and refrigeration in one visit.
Licences: QBCC 1126780 • Electrical Licence: 71053
Call: 0482 080 423

One crew, all trades — licensed plumber + electrician + refrigeration tech together
Measured diagnosis — airflow, coil temps (non-invasive), electrics, water-side flow; we prove it, not guess it
Fixed price first — you approve before we start
Keep-you-going plan — element-only mode (if fitted) or a temporary hot water unit while parts arrive
Respect for tight side paths, sloped blocks and shared drives off Alexander Dr / Nerang–Broadbeach Rd

Wind + leaf fluff on the slopes → evaporator coil mats over, fan gets noisy, defrost runs too often.
We deep-clean the coil, test fan amperage/capacitor and confirm defrost logic & drainage.
Short power blips in storm season → controller clock drifts; unit misses off-peak and never catches up.
We correct the timer, verify element/compressor draw and re-set programs.

Sensor drift (tank/coil thermistors 8–15 °C out) → controller “thinks” storage is hot or coil is frozen when it isn’t.
We compare readings to real temps and replace out-of-spec sensors.
Tempering/NRV valves in older duplex pockets → storage is hot but taps mix too cold.
We test/replace valves and set safe, steady outlet temperature.
Pests & moisture in outdoor control boxes → “ghost” codes and RCD trips.
We isolate safely, inspect boards/wiring, replace compromised parts and seal entries.

Night-time drone or intermittent grinding from the outdoor unit
Snowflake/“ice” icon after windy days
Shower temps swing from warm to cool, or never exceed ~40–45 °C
Breaker/RCD trips when the unit starts
Tank gauge shows hot, but taps are tepid (tempering valve issue)
Complaint: rumble at night, tepid evening showers, snowflake symbol after windy days.
Find: coil clogged with leaf fluff, weak fan capacitor, tank sensor ~11 °C low, controller clock 35 mins slow, tempering valve mixing too cold.
Fix: coil clean, new cap + sensor, timer corrected, defrost verified, tempering valve reset.
Result: quiet operation and stable ~55–60 °C storage without overnight thrash.

Air & refrigeration: coil state, fan speed/amperage, airflow path, non-invasive discharge/suction temps, start/run capacitors, vibration/noise
Electrical: supply quality, RCD behaviour, controller clock/program, element/compressor draw
Plumbing: inlet pressure, tempering valve & non-return performance, leaks, anode (where applicable)
Proof before we leave: outlet & storage temps and recovery time, with photo notes for owners/strata
Repair when the tank is sound and the fault is a part (sensor, fan, capacitor, valve, element).
Replace when the cylinder is corroded, compressors keep faulting, or parts are obsolete. We’ll size a new heat pump for your household/tariff, install it, remove the old unit and register warranties.
Stiebel Eltron (WWK) • Rheem (Ambiheat/HDc) • Rinnai • Sanden Eco • Reclaim Energy • iStore • Chromagen • Thermann • Dux Airoheat • Quantum (older)
Photo of the unit’s rating/serial label
Any fault codes or flashing icons
Active leak? Turn off the isolation valve
Tripping? Leave the HWS breaker off until we arrive
Call 0482 080 423 or text your unit-label photo with a one-liner about the fault. We’ll confirm a time window and what to expect.

No. Usually a clogged coil or weak fan capacitor. We clean the coil, test the fan/cap and verify defrost to quiet it down.
Often. Power blips shift the controller clock so the unit misses off-peak. We correct timers, verify draw and recalibrate sensors.
Leave it off. Trips indicate moisture, a failing element/capacitor or a board fault. We test safely and isolate the culprit.
Commonly a tempering valve mixing too cold. We test/replace it and set a safe outlet temperature.
Usually yes: element-only mode (if fitted) or a temporary hot water unit until parts arrive.
Same day service at no extra cost
All brands, makes and models
Get hot water today
Over 20 years in business
Solar accredited plumbers & elecricians
Fully insured
We have honesty & integrity
We carry temporary hot water systems so if for any reason it cant be fixed on the day you can get hot water now!